Applying no-contact working mode, relible in performance without mechanical movements
Powerful induced magnet is used,which can maximally increase anti-interference ability of the system
The system can conduct scientific calculation according to mathematical equation and automatically
revise testing error,with self-return ability in empty load
Self-study or manual displacement setting way is applied,with convenient operation
UnSymmetrical Duplex Serial Communication BUS(USDSC-BUS)
Analog output 0~10V. -10~10V
Analog output 4~20mA(*OMS-220)
Technical data loadsensor | Technical data control unit 220 | ||
Power supply voltage | 24V.ripple(P-P)10% | Power supply voltage | AC/DC14V~65V |
Sensing object | Magnetism Object | Power dissipation | ≤4W |
Measuring range | 2~9mm(±2%) | Alarm relays | Light load,over load |
Connection cable | 1.2m(USDSC-BUS) | Analog voltage output | 0~10V,-10~10V |
Temperature range | 0℃~70℃ | Analog current output | 4~20mA |